Safety Valve – closed completion

Table of Contents

Overview

Suitable for:RITTER Drum-type Gas Meters and Bellows-type Gas Meters
Gases:toxic
Set pressure:Type 1: 50 mbar
Type 2: 500 mbar
Type 3: 1 bar
Maximum flow rate:
(with air at 0 °C)
Type 1: 11 Nm3/h
Type 2: 24.8 Nm3/h
Type 3: 35.9 Nm3/h
Material:1.4571 / 1.4581
Function:spring loaded
Connection:pipe connection
Operating temperature: (1)-60 °C to +280 °C
Installation position:vertical
Sealing:Viton
RITTER Safety Valve – closed completion

(1) Please mind the temperature range of the gas meter!

Caution: If the pressure will exceed the above-mentioned set pressure, the safety valve will open. However, if the flow rate from the gas source exceeds the above-mentioned max. flow rate, the valve would not be able to vent the meter quickly enough.

This would built-up a pressure inside of the meter and may destroy the gas meter despite of the opened valve!

Specifications

InletOutletDimensionsSet pressureWeight
ESE (mm)D (mm)l (mm)ASAtH1 (mm)H2 (mm)H3 (mm)SW (mm)d0 (mm)p (bar)(kg)
G 3/4343216G 1/2401420020518532160.05 / 0.5 / 11

V 1.0 / Rev. 2024-02-07 / Subject to alterations.