RITTER Biogas Batch Fermentation System BBFS-18 (Standard)

Table of Contents

Basic Elements BBFS-18

HXXO20201128141540 2560
  • Suitable for max. 18 x 0.5 / 1.0 / 2.0 ltr PMMA Fermentation Bottles
  • Air circulation by 2 powerful fans for homogeneous heat distribution
  • Control panel with LCD display for digital temperature setting, increment 1°C
  • Integrated mainboard for operation of stirring units
  • RJ12 interface for bus line to the »SIM« signal interface module for controlling the oven temperature and speed/interval operation of the stirring devices (with RIGAMO V4.x)
Dimensions W 750 mm x D 750 mm x H 300 mm Weight 39.0 kg
* Mounting space for rear cable connections: +50 mm
Read MoreHeating Oven Type BBFS-18
HXXO20201129111701PE 1600
  • Suitable for simple and compact installation of max. 18 MilliGascounters and 18 optional CO₂absorption bottles
  • Frame made of aluminium, shelves made of stainless steel 1.4571
Rack for BBFS-18 Dimensions W 810 mm x D 370 mm x H 950 mm Weight 13.5 Kg
Read MoreRack for BBFS-18
Roller Table for Heating Oven BBFS-09 & BBFS-18

Features

  • Wheeled table for setting up the heating oven for fermentation system BBFS-18
  • Total height incl. standing heating oven = standard height laboratory tables (920 mm)

Design

  • Table frame with 4 lockable wheels
  • 1 additional storage compartment below the heating oven
  • Suitable for holding the movable rack for the installation of MilliGascounters and absorption bottles

Materials

  • Frame made of aluminium profiles, table plates made of PE-blue
Table for BBFS-18 Dimensions W 820 mm x D 720 mm x H 620 mm
The illustration shows the tables with the ovens in place with the rack for MilliGascounters and CO₂ absorption bottles. The rack can be moved forward/backward for easy installation and handling of the MilliGascounters and CO₂ absorption bottles. The gas sampling bags (option) can be attached to the horizontal aluminium profiles.
Read MoreRoller Table for Heating Oven BBFS-18 (Option)
HXXO20200628133408PE 1600

Feature highlights

  • Absolute gas-tight by magnetic coupling between stirring motor and stirring blade
  • Various bottle sizes: 0.5 / 1 / 2 ltr – custom sizes on request
  • High breaking strength by PMMA material (no fragile glass gas outlet nozzle)
  • Custom stirring blades available

Technical Data

  • Stirring speed adjustable from 1 to 30 r/min *
  • Interval stirring with freely selectable interval times *
  • Suitable for media with low and high viscosity (≤ 450 mm2/sec)
  • Temperature range: 10 – 55 °C
  • Max. pressure: 100 mbar
  • Material fermentation bottle: PMMA crystal-clear
  • 2 connection ports: 1 x gas outlet, 1 x purging of heads space or sample taking, PVDF screw-type tube connection for tube Øi 4 mm, Øo 6 mm

* with »RIGAMO« V4.x software

Read MorePMMA Fermentation Bottle with Stirring device
HXXO20200630211310PE 1600

Type: MGC-1 PMMA / Material: Casing PMMA, measurement cell PVDF

  • Measuring range: 1 ml/h to 1 ltr/h
  • Measuring accuracy: ±3% across the whole flow rate range (better ±1% with »RIGAMO« software by dynamic correction of measurement errors)
  • Including individual calibration certificate
  • Volume measurement cell: 3 ml
  • Equipment: Digital display, 200 ml packing liquid, 1.5 m connection tube, cleaning tool, syringe and bubble level (1 piece each for up to max. 5 pc.)
  • Resolution (= min. measurement increment): 3 ml
  • Max. operating temperature 60 °C
  • Max. overpressure: 100 mbar
PMMA / PVDF Dimensions ø 96 mm x H 112 mm Weight 475 g

For a detailed description see RITTER MilliGascounters and data sheet »MilliGascounter MGC-1 PMMA«.

Read MoreMGC-1 PMMA
HXXO20201129105713PE 1920

Overview

  • Types: 1-/3-/9-/18-Channel
  • Central interface module for RITTER Biogas Batch Fermentation System BBFS V4.x

Functions

  • Data transmission of gas volume and temperature of a RITTER Gas Meter
  • Normalisation (temperature and pressure compensation) of gas volume and volume flow
  • Data transmission for temperature control of the Heating Oven
  • Data transmission for stirrer control of the Fermentation Bottles
  • Conversion of data into USB signals for connection to PC
Read MoreSignal Interface Module (»SIM«)

Components for CO₂ Absorption (Option)


amber youtility 04 1

Absorption solution

  • 3-molar caustic potash solution (KOH 3 mol/ltr in aqua dest.)
  • Filling quantity per absorption bottle: 250 ml
  • Delivery in bottles of 1 ltr
Please note: Due to transportation restrictions, the absorption solution might has to be purchased locally. Please contact RITTER.
Read MoreAbsorption solution

More Options

Roller Table for Heating Oven BBFS-09 & BBFS-18

Features

  • Wheeled table for setting up the heating oven for fermentation system BBFS-09
  • Total height incl. standing heating oven = standard height laboratory tables (920 mm)

Design

  • Table frame with 4 lockable wheels
  • 1 additional storage compartment below the heating oven
  • Suitable for holding the movable rack for the installation of MilliGascounters and absorption bottles

Materials

  • Frame made of aluminium profiles, table plates made of PE-blue
Table for BBFS-09 Dimensions W 570 mm x D 570 mm x H 620 mm
The illustration shows the tables with the ovens in place with the rack for MilliGascounters and CO₂ absorption bottles. The rack can be moved forward/backward for easy installation and handling of the MilliGascounters and CO₂ absorption bottles. The gas sampling bags (option) can be attached to the horizontal aluminium profiles.
Read MoreRoller Table BBFS-09
HXXO20180426160232 3000 2560
  • 1 x Connection for gas outlet port, PVDF screw-type tube connection  øi 4 mm, øo 6 mm
  • 1 x Connection for flushing of headspace or sample extraction, PVDF screw-type tube connection øi 4 mm, øo 6 mm
  • Various bottle sizes: 0.5 / 1 / 2 ltr - custom sizes on request
  •  High breaking strength due to PMMA material (without fragile glass gas outlet nozzle)
0.5 ltr Dimensions ø H 110 mm x D 105 mm Weight 0.25 kg
1.0 ltr Dimensions ø H 190 mm x D 105 mm Weight 0.4 kg
2.0 ltr Dimensions ø H 350 mm x D 105 mm Weight 0.7 kg
Read MorePMMA Fermentation Bottle without Stirring Device
Stirring device for RITTER PMMA fermentation bottles
  • Incl. magnetic coupling for absolute gas tightness of fermentation bottle
  • With intervalic stirring (1 min / 1 min)
  • Suitable for media with low and high viscosity ≤ 450 mm²/sec (≙ 65 sec capillary flow cup 6 mm DIN EN ISO 2431)
  • Step motor 2 ampere, 15 rpm
  • Custom stirring blades available
0.5 ltr Dimensions of stirring blade W 80 mm x H 45 mm Weight ~ 0.7 kg
1.0 ltr Dimensions of stirring blade W 80 mm x H 125 mm Weight ~ 0.7 kg
2.0 ltr Dimensions of stirring blade W 80 mm x H 285 mm Weight ~ 0.7 kg
Read MoreStirring Device for RITTER PMMA Fermentation Bottles
RITTER BBFS+ Gas Analysis

The RITTER Biogas Batch Fermentation System (BBFS) allows the world-wide unique combination of:

  • biogas fermentation tests
  • data acquisition of volume and flow rate
  • gas analysis of CH₄ and CO₂ as an option

… from up to 18 gas sources.

For this purpose, 9 high-precision RITTER »MultiGas« NDIR (non-dispersive infrared) Sensors are installed in one casing. Up to 2 casings can be attached to the rack the Biogas Batch Fermentation System (BBFS), enabling the analysis of biogas and many other gases in research and development labs.

V 1.0 / Rev. 2024-09-05 / Subject to alterations.

Read More»MultiGas« Sensors for BBFS

Small Parts (always included)

RITTER Check valve with 2 tube nozzles

Check valve with 2 tube nozzles

  • 1 check valve per MilliGascounter
  • Incl. tube nozzles for tube øi 4 mm / øo 6 mm
  • Materials: Housing PC, valve body Silicone, tube nozzles Polypropylene
  • Function: Prevents reverse flow* of …
    • … packing liquid into Fermentation Bottle when used with MilliGascounter
    • … absorption liquid into Fermentation Bottle when used with CO₂ Absorption Bottle
  • Easy mounting in tubing behind filter and in front of MilliGascounter
* Reverse flow may be caused due to an underpressure in the Fermentation Bottle for example by a decrease of temperature in the bottle.
Read MoreCheck valve with 2 tube nozzles

Gas Analysis (Option)

RITTER BBFS+ Gas Analysis

The RITTER Biogas Batch Fermentation System (BBFS) allows the world-wide unique combination of:

  • biogas fermentation tests
  • data acquisition of volume and flow rate
  • gas analysis of CH₄ and CO₂ as an option

… from up to 18 gas sources.

For this purpose, 9 high-precision RITTER »MultiGas« NDIR (non-dispersive infrared) Sensors are installed in one casing. Up to 2 casings can be attached to the rack the Biogas Batch Fermentation System (BBFS), enabling the analysis of biogas and many other gases in research and development labs.

V 1.0 / Rev. 2024-09-05 / Subject to alterations.

Read More»MultiGas« Sensors for BBFS