RITTER MultiGas Ультрафиолетовый датчик NDUV

RITTER MultiGas Ультрафиолетовый датчик NDUV

Обзор

O3 CL2 H2S SO2 NO2

The RITTER MultiGas Sensors NDUV Module (non-dispersive UV sensor) has also been specially developed for use in high quality gas analysis. In the design phase special emphasis was placed on high stability and a low detection limit. These goals could be fully achieved by using high-performance light-emitting diodes (UV-LED) and gas discharge lamps (EDL) which were adapted to the requirements of gas detection technology. In the spectral range from 200 nm to 405 nm, nitrogen oxides, aromatic hydrocarbons, ketones, ozone, sulfur dioxide and halogens can be used with this novel sensor platform, partly detected reliably in the ppb range.

The various photometric components such as detectors, emitters, measuring sample cell, etc. will be assembled user-specifically in a high-quality tabletop casing by RITTER.
RITTER MultiGas Sensorgehäuse

Applications

Characteristics and Benefits

  • Group of detectable gases:
    O3 CL2 H2S SO2 NO2
  • Measurement technology: Innovative NDUV-Sensor (non-dispersive ultraviolet sensor)
  • Погрешность измерений ±2% of Full Scale (F.S.)
  • No cross-sensitivity to H2
  • Operating temperature: 5 – 45 °C
  • Operating pressure: 800 – 1200 mbar (hPa) abs.
  • Flow rate range: 1 ltr/day – 100 ltr/h
  • Warm-up time: 1 min
  • Response time (t90): ≈ 1-2 sec depending on gas
  • In tabletop casing, overall dimensions W x H x L 171 x 85 x 246 mm, weight approx. 1,9 kg
  • Gas connection: PVDF screw-type tube connection for tube Øi 4 mm, Øa 6 mm
  • Power supply: 24 VDC (incl. power plug 100 – 240 VAC / 24 VDC)
In contrast to photometric NDUV sensors the lifetime of electrochemical sensors for measurement of H2S is limited. Please note that lifetime data for such sensors are given for air and not for measurement of H2S. For H2S concentrations > 200 ppm the lifetime is reduced, for concentrations > 1000 ppm critical. While the measurement performance of UV-LED is constant, EC sensors are becoming »deaf«.

Recalibration

  • Readjustment of the zero-point is recommended once a week.
  • Contamination of the measuring cuvette can lead to shifting of the end-point. Due to the integrated filter, re-adjustment of the end-point is generally not required – but can be performed once a year.
  • Additionally, cartridges filled with an inert and the respective test gas for recalibration of the zero and end-point can be provided.
  • Long-term drift is < 1% of Full Scale (F.S.) / 24 h.

Options / Additional Sensors

Датчик кислорода

  • Электрохимический датчик
  • Диапазоны измерения: 0 - 25% или 0 - 100%
  • Точность измерения ±2% диапазона (полная шкала)
  • Разрешение: < 0,5% диапазона (полная шкала)
  • Время отклика (t90): ≈ 15 с; автоматическая версия ≈ 5 с
  • Срок службы: около 5 лет

датчик давления

  • Компенсация давления измеренных концентраций газа
  • Диапазон измерения: 800 - 1200 мбар абс.
  • Точность измерения ±1% от диапазона (полная шкала).
  • Разрешение: 1 мбар
  • Время отклика (t90): 1 с
  • Вкл. температурную компенсацию

датчик влажности

  • Датчик влажности полимерный
  • Диапазон измерений: 0-100% ОТН. ВЛ.
  • Точность измерения ±2% диапзона отн. влажности (полная шкала)
  • Разрешение: ±1% отн. вл.
  • Время отклика (t90): 12 с
  • Вкл. температурная компенсация
  • Указанные значения: относительная влажность в % отн. вл.

аналоговый выходное напряжение

  • Модуль аналоговых выходных напряжений позволяет выводить значения концентрации газа для 4-х различных газов на 4-х отдельных каналах
  • Уровни напряжения:
    • 0 – 2 V
    • 0 – 5 V
    • 0 – 10 V

V 1.0 / Rev. 2021-05-15 / Возможны изменения.