Data Acquisition Software »RIGAMO« • Ficha de Dados
Features
- Windows software for data acquisition of gas volume and flow rate from up to 24 RITTER Gas Meters to a PC USB port.
- Support of multi-core processors
- Graphical and tabular display of measurement data
- Storing of data
- Print out (separately or in any combination) of Diagram / Test parameters / Measured values in tabular form
- Export of stored data to Microsoft Excel® spread-sheet (Excel 2003 or higher)
- Automatic correction of the dynamic (flow rate dependent) measurement error (MGC only)
Please note: »RIGAMO« can only started once at a time on a single PC.
No support of bi-directional recognition of the measuring drum rotation with Pulse Generator V4.01
Interface
Main Window (Data Window)
- Area 1: Display of port status
- Area 2: Tabular display of data for respective ports in real time
- Area 3: Tick boxes for display »show« / »no show« of graphs
- Area 4: Indicator for online / offline display of graphs
- Area 5: Diagrams for gas volume and flow rate
- Area 6: Indicator of processor load status and »DIM« connection status
- Area 7: Buttons »Start/Stop« of data acquisition
- Area 8: Menu item “Diagram” for displaying diagram related settings
Diagram Settings
- Area 1: Selection of graph updating mode (automatically/manually)
- Area 2: Number of last measurement data to show in diagram
- Area 3: Dimensions of diagram axes
Please note: The illustrations shown above represent RIGAMO Software V 3.2 Beta. The user interface of previous versions may differ. For further information, please refer to the documentation provided with the software.
System Requirements
- 1 freie USB-Schnittstelle
- Medidor de gás com gerador de pulso embutido (padrão MilliGascounter)
- Módulo de entrada digital »DIM« (opcional)
- Sistema operacional: Windows® 7/8/10
- Microsoft Excel® 2003 ou superior para exportação de dados para Excel®
- Desempenho recomendado do processador: ≥1,5 GHz
- Memória de acesso aleatório (RAM): ≥500 MB
- Monitor 17” (otimizado para resolução de monitor de 1280x 1024 pixel ou superior)
Por favor, note que: Nenhum outro software da National Instruments deve ser instalado no respectivo computador, pois pode entrar em conflito com o software RIGAMO.
Um conversor padrão "USB para RS232" para conexão à porta COM não pode ser usado.
Display Example
E. g. data acquisition from 3 gas meters; red graphs: volume; blue graphs: flow rates
Data Export to Excel
System requirement: Microsoft Excel® 2003 or a later version
Export example of four data files:
The data of each data file (parameters plus measurement data) are exported into a separate table. Additionally, a blank table is created with the name of the export file (see red mark in the window above).
Configuration Example
Schematic of a completed configuration of RITTER Gas Meter, Digital Input Module, PC and RIGAMO (Example for connection of 4 gas meters)
Downloads
Advertência: Estes arquivos ZIP são maiores que 200MB!
V 3.1 / Rev. 2022-06-28 / Sujeito a alterações.
https://www.ritter.de/pt-pt/folhas-de-dados/data-acquisition-software-rigamo/
Dr.-Ing. RITTER Apparatebau GmbH & Co. KG · Coloniastrasse 19-23 · D-44892 Bochum · Alemanha
Para perguntas, favor contatar mailbox@ritter.de ou seu parceiro de distribuição local (em nossa página de resumo)