BG 100 • डाटा शीट

Performance Data
Minimum flow Qmin | 1,000 | ltr/h |
Standard flow Qstandard | 95,000 | ltr/h |
Maximum flow Qmax | 160,000 | ltr/h |
Measurement accuracy (2) | 2 | % |
Measuring cavity capacity | 120 | ltr/U |
Temperature range | 5 to 40 | °C |
Maximum gas inlet pressure | 500 | mbar |
Minimum differential pressure (1) | 1 | mbar |
Minimum dial division | 0.4 | ltr |
Indication dial plate | 100 | ltr |
Maximum indication value (3) | 999,999,990 | ltr |
Weight | 130 | kg |
- (1) Differential pressure (= pressure loss) gas inlet gas outlet
- (2) Across the measuring range in relation to the calibration value at nominal flow
- (3) Standard Totalizing Roller Counter
No reverse flow direction possible!
Models (materials)
- Casing: zinc-coated steel sheet (soldered) with outside also lacquered
- Measuring unit: Tinplate
- Bellows (within measuring unit): textile-reinforced nitrile rubber (Perbunan®)
- Rod linkage: Polyamide
- Slide gate: Bakelite
Standard Equipment
- 8-digit Totalizing Roller Counter
- Flanschanschluss DN 100, gemäß DIN 2642-PN10
- Large, One-needle Dial
- Magnet-Kupplung (zwischen Messwerk und Zählwerk)
- Twin-Chamber Measuring Unit
Built-in Options
Accessories
- Thermometer (BG)
- Manometer for pressure pmax = 60 mbar
- Electronic Display Unit »EDU 32 FP«
- Nozzles for flexible tube connection
V 3.0 / Rev. 2022-06-27 / Subject to alterations.
The most recent version of this data-sheet can be found at …
https://www.ritter.de/hi/%E0%A4%A1%E0%A4%9F-%E0%A4%B6%E0%A4%9F/bg-100/
Dr.-Ing. RITTER Apparatebau GmbH & Co. KG · Coloniastrasse 19-23 · D-44892 Bochum · Germany
For questions please contact mailbox@ritter.de or your local distribution partner (on our overview page)