Safety Valve – closed completion • برگه اطلاعات
Suitable for: | RITTER Drum-type Gas Meters and Bellows-type Gas Meters | |
Gases: | toxic | |
Set pressure: | type 1: 50 mbar type 2: 500 mbar type 3: 1 bar | |
Maximum flow rate: (with air at 0°C) | type 1: 11 Nm3/h type 2: 24.8 Nm3/h type 3: 35.9 Nm3/h | |
Material: | 1.4571 / 1.4581 | |
Function: | spring loaded | |
Connection: | pipe connection | |
Operating temperature: (1) | -60 °C to +280 °C | |
Installation position: | vertical | |
Sealing: | Viton |
(1) Please mind the temperature range of the gas meter!
Caution:
If the pressure will exceed the above-mentioned set pressure, the safety valve will open. However, if the flow rate from the gas source exceeds the above-mentioned max. flow rate, the valve would not be able to vent the meter quickly enough.
This would built-up a pressure inside of the meter and may destroy the gas meter despite of the opened valve!
Inlet | Outlet | Dimensions | Set pressure | Weight | |||||||||
E | SE | d | l | A | SA | t | H1 | H2 | H3 | SW | d0 | p | |
mm | mm | mm | G | mm | mm | mm | mm | mm | mm | mm | bar | kg | |
G 3/4 | 34 | 32 | 16 | 1/2 | 40 | 14 | 200 | 205 | 185 | 32 | 16 | 0.05 / 0,5 / 1 | 1 |
V 1.0 / Rev. 2023-03-15 / منوط به تغییرات.
The most recent version of this data-sheet can be found at …
https://www.ritter.de/fa/safety-valve-closed-completion/
Dr.-Ing. RITTER Apparatebau GmbH & Co. KG · Coloniastrasse 19-23 · D-44892 Bochum · Germany
For questions please contact mailbox@ritter.de or your local distribution partner (on our overview page)
https://www.ritter.de/fa/safety-valve-closed-completion/
Dr.-Ing. RITTER Apparatebau GmbH & Co. KG · Coloniastrasse 19-23 · D-44892 Bochum · Germany
For questions please contact mailbox@ritter.de or your local distribution partner (on our overview page)